Sinetica Corporation Safety Notice - 11th September 2006
Product: Hawk-i
Products Affected: Hawk-i models;
Part Numbers:
- ZAWM-01
- ZAWM-01C,
- ZAWM-02,
- ZAWM-03,
- ZAWM-03A,
- ZAWM-04
- ZAWM-05
- ZAWM-06
Statement:
The Hawk-i unit is supplied in Europe to conform to European standards 89/336/EEC (Electro Magnetic Compatibility) and 73/23/EEC (low Voltage Directive).
To conform to these standards the relay output contacts supported by the Hawk-i unit may only be used to switch electrical voltages of 50VDC or less.
An error in the user manual, and on the printing of some Hawk-i unit enclosures incorrectly states that Hawk-i relay-3 and Hawk-i relay-4 may be used to switch 240VAC – this is incorrect.
Hawk-i relay-3 and Hawk-i relay-4 may only be used to switch electrical Voltages of 50VDC or less and electrical loads of up to 40W.
Required Actions:
If the Hawk-i unit’s relays are being used to switch voltages greater than 50VDC/VAC, then immediately power down the high voltage source and then disconnect the high Voltage source from the Hawk-i unit. Contact Sinetica.
Destroy/delete any printed or electronic “Hawk-i Unit User Manuals”. Please use the revision 2.00 manual available via download from the Sinetica Web site at the above 'Support' link.
Please check the physical Hawk-i unit labelling, for relay-3 and relay-4 (on the top surface of the Hawk-i unit case). If the text indicates 240VAC rating, please contact Sinetica.
If you are unsure about any of the information contained within this notice please contact Sinetica for further advice.
| |
|
|
| Sinetica Contact Information: |
Tel UK |
0845 456 3561 |
| |
Fax UK |
0845 456 3562 |
| |
Tel Int |
+ 44 (0) 1291 674660 |
| |
Fax Int |
+ 44 (0) 1291 672796 |
| |
Mail |
Sinetica Corporation Ltd.
Willow House, Llancayo Court,
Usk, Monmouthshire
NP15 1HY,
United Kingdom
|
|